Full-scale test on steel arch with unconventional strap under lateral and gravity loads.

Authors

  • Carlos Zavala Facultad de Ingeniería Civil, Universidad Nacional de Ingeniería, Lima - Perú
  • Jorge Gallardo Facultad de Ingeniería Civil, Universidad Nacional de Ingeniería, Lima - Perú
  • Patricia Gibu Facultad de Ingeniería Civil, Universidad Nacional de Ingeniería, Lima - Perú
  • Claudia Honma Facultad de Ingeniería Civil, Universidad Nacional de Ingeniería, Lima - Perú

DOI:

https://doi.org/10.21754/tecnia.v12i2.494

Abstract

A non conventional purlin with triangular section and cross diagonals is proposed to be used in Steel Arch Structures. For this purpose a full scale arch of 7 meters span with 6 meters purlins, was built in order to perform a loading test under extreme gravity loads and monotonic test under
lateral load. To prove the interaction between the supporting arch and the purlins, incremental gravity load was applied over each element. Elastic deflection of 0.007 m for 931 N/m load was found which is under the demand of AISC-LRFD (L/360). Maximum deflection of 0,013 m for 1470
N/m load was found at the end of the test. To prove how effective is the bolt connection between the purlin and the arch, a full scale test under lateral monotonic load applied at one extreme was performed, to simulate the extreme wind load over the structure. A 2254 N load produces 0,05 m of lateral displacement on the system. This value was almost the beginning of the non-linear behavior of the structural system.

Downloads

Download data is not yet available.

References

[1] Luis Zapata B. "Wind action on buildings. The Civil Engineer No. 99, November Ed., Lima Perú. CIP Editions, 1995 (in Spanish).

[2] E. Booth, J. E. Martínez-Rueda, "Resistance against earthquakes and typhoons on low cost housing in Philippines", Structures to Withstand Disasters. The Institution of Civil Engineers. London 1995.

[3] American Institute Of Steel Construction, "Manual of Steel Construction Load and Resistance Factor design", Volume 1.USA, 1995.

[4] Peruvian Construction National Standards. "Load Standards for Building Structures" NT- 020, SENCICO, 1997 (in Spanish).

Published

2002-12-01

How to Cite

[1]
C. Zavala, J. Gallardo, P. Gibu, and C. Honma, “Full-scale test on steel arch with unconventional strap under lateral and gravity loads”., TEC, vol. 12, no. 2, Dec. 2002.

Issue

Section

Articles